Data Centre Fire Services 

Protecting India’s Digital Backbone with Zero Downtime Precision

High-Flame Risk. Zero Margin for Error 
In the age of cloud computing, AI, and hyperconnectivity, data centres are the heart of digital India. At Act Masters, we understand that even a second of downtime can mean a loss of millions or worse, a breach of trust.

That’s why we specialize in end-to-end Fire Safety Solutions for Data Centres and Disaster Recovery Sites (DRS) ensuring mission-critical operations never skip a beat.

What We Offer

What We Offer
Risk-Based Fire Safety Design

Tailored fire protection systems based on:

  • Server density and room layout
  • Airflow and cooling patterns
  • Tier classification (Tier I–IV)
  • Clean agent compatibility (e.g., FM-200, NOVEC 1230)

Clean Agent Fire Suppression Systems

We deploy environmentally safe, residue-free suppression systems that protect sensitive equipment without damaging electronics.

VESDA & Early Detection Technologies

Our Very Early Smoke Detection Apparatus (VESDA) detects threats before they escalate—providing crucial response time to mitigate risk.

Zoned & Redundant Suppression Planning

Multi-zone suppression strategies for modular DCs and large hyperscale setups. Redundancy ensures one system failure doesn’t compromise protection.

AMC & 24/7 Monitoring

Act Masters offers Annual Maintenance Contracts (AMCs) with real-time performance tracking, ensuring round-the-clock readiness.

Why Act Masters?
NBC2016+

Ready (and advocating for geo-specific DC fire codes)

IT/OT environment

Specialized experience in high-risk IT/OT environment

NFPA 75, NFPA 2001, ISO/IEC 27001

Aligned with global standards like NFPA 75, NFPA 2001, ISO/IEC 27001

Seamless integration

Seamless integration with building management and emergency systems

Trusted

Indian Standards for materials and system design 

Our team ensures your plant remains audit-ready and fully compliant at every stage—from design and documentation to commissioning and NOC liaison. 
Why Choose Act Masters

NBC2016+ Ready (and advocating for geo-specific DC fire codes)

Specialized experience in high-risk IT/OT environments

Aligned with global standards like NFPA 75, NFPA 2001, ISO/IEC 27001

Seamless integration with building management and emergency systems

Trusted

We Are Creating a Better Tomorrow

FAQs
Data centres require non-conductive, residue-free suppression to protect sensitive electronics. We recommend clean agents such as FM-200 and NOVEC 1230, which extinguish fires rapidly without damaging equipment or leaving corrosive residues.
VESDA (Very Early Smoke Detection Apparatus) continuously samples air for microscopic smoke particles, identifying a threat long before conventional spot-type detectors. This extra lead time is critical in data halls, allowing managers to isolate zones and deploy suppression before a fire can grow.
In general, water-based sprinklers pose too high a risk of collateral damage in mission-critical IT spaces. They’re best reserved for peripheral areas (e.g., lobbies, corridors). Inside server rooms, clean agents and inert gas systems provide effective fire control without risking expensive hardware.

A zoned approach divides your data centre into multiple compartments, each with its own suppression system. Redundancy means backup systems support each zone in case one fails. Together, they ensure that a single point of failure won’t compromise the entire facility, maintaining continuous protection.

Regular maintenance is essential. We recommend quarterly inspections of detection and suppression equipment, plus an annual Comprehensive Performance Test under our AMC (Annual Maintenance Contract). This schedule ensures every component remains fully operational and compliant with evolving standards.
Contact Us
Act Masters Private Limited, Cabin No.3A, Second floor of SCO -18,Panchkula, Sector 16, Haryana.
Get In Touch